Skip to main content

Table 1 Magnetic resonance imaging (MRI) parameters

From: The relationship between chronic PTSD, cortical volumetry and white matter microstructure among Australian combat veterans

Parameter 

T1-weighted

MPRAGE

T2-weighted

FLAIR

Diffusion-weighted

Images

Field map

Scan timing

 Echo time (TE, ms)

2.93

82

130

5.19 / 7.65

 Repetition time (TR, ms)

2300

6000

8900

400

 Inversion time (TI, ms)

900

2070

–

–

 Flip angle (°)

9

125

90

60

 Bandwidth (BW, Hz/pixel)

241

200

992

260

 Echo train length (ETL)

1

24

1

1

 b-values

–

–

0, 3000

–

Acquisition timing

 Frequency (number of pixels)

240

320

120

64

 Phase (number of pixels)

256

320

120

64

 Phase field of view (FOV, %)

0.94

1.00

1.00

100

 Gradient directions

–

–

64

–

 b-zeros

–

–

1

–

Scanning range

 FOV (mm)

253 × 270

250 × 250

240 × 240

192 × 192

 Spacing (mm)

1.05

0.78

3

3.75

 Slice thickness (mm)

1.2

2.5

2

3

 Slices

192

60

50

36

  1. MPRAGE magnetization-prepared rapid gradient-echo, FLAIR fluid-attenuated inversion recovery