Skip to main content

Table 3 Generalized linear regression analysis of time to fascial closure, and cumulative fluid balance

From: Bioelectrical impedance analysis-guided fluid management promotes primary fascial closure after open abdomen: a randomized controlled trial

Group

Time to fascial closure

P

Cumulative fluid balance

P

βcoefficient

Standard error

βcoefficient

Standard error

BIA vs. TRD

−3.66

0.49

< 0.001

−6632.80

746.91

< 0.001

  1. Adjusted for age, male, BMI, severity of illness (mechanism of injury, AIS, ISS, APACHE II and SOFA score), indications, number of reoperations, number of vasopressors and intraoperative fluid volume. BIA bioelectrical impedance analysis, TRD traditional fluid resuscitation. P-values less than 0.05 were considered as statistically significant